Air-to-Water Heat Pumps in Ontario: Radiant Floors Heated by a Heat Pump: What Works, What Needs Backup, and What to Watch

If you love radiant floors and want off gas or propane, an air-to-water heat pump is the obvious question. It makes warm water instead of warm air, and radiant slabs want exactly the kind of lukewarm water a heat pump makes best.

It is also one of the least understood systems in Ontario, with few experienced installers. Here is what it does, what it needs, and how to design it so it actually keeps up in January.

Radiant slabs want lukewarm water. That is exactly what a heat pump makes best.
Design It to Keep Up
Heat loss at your design temperature and a radiant design built around low water temperatures, with backup sized to the gap.
Free quote · No spam · No obligation
How It Works

An outdoor heat pump pulls heat out of the air and puts it into water. That water goes through your radiant floors, panel radiators or fan coils, just like boiler water.

The lower the water temperature the system needs, the more efficient the heat pump runs. That is why radiant slabs and air-to-water are such a good match, and why old radiators that need very hot water are a poor one.

The key design question

What water temperature does your floor need on the coldest day? The lower it is, the better the heat pump works. That comes from the heat loss and the radiant design together.

What the Design Has to Cover

The Heat Loss

Room by room, at your design temperature. See CSA F280 heat loss.

Low Water Temperature

Tube spacing and floor design that deliver the heat with the coolest water possible.

Output at Design Temperature

The heat pump’s real output in the cold, not its rating on a mild day.

Backup Heat

An electric element or a boiler for the gap on the coldest days. See backup heat sizing.

Buffer Tank and Controls

Many systems use a buffer tank to keep the heat pump from short-cycling. The controls matter as much as the hardware.

Ventilation

Radiant does not move air. The house still needs an HRV, shown on the ventilation summary (RMVDS) for the permit.

Where It Makes Sense

New Builds With Slab Radiant

The best match. Design the slab for low water temperatures from day one.

ICF and Tight Houses

Small loads, steady demand. See ICF heat loss.

Off Gas, Off Propane

Replaces a propane or oil boiler on an existing radiant system, if the floors can work at lower temperatures.

Garages and Shops

A heated slab in a shop is an easy match.

Air-to-Water vs the Alternatives

Against an electric boiler, it uses a fraction of the electricity on most days, but costs more up front. Against geothermal, it is cheaper to install but less efficient on the coldest days. Against gas, it depends on your rates and your house.

The heat loss is where every one of those comparisons starts.

Thinking air-to-water? Send the drawings. We size the load and design the radiant for low water temperatures.

Get Free Quote →
Air-to-Water Questions
What is an air-to-water heat pump?

A heat pump that makes warm water instead of warm air. The water goes to radiant floors, panel radiators or fan coils, the same way boiler water would.

Do air-to-water heat pumps work in an Ontario winter?

Cold-climate models keep working well below freezing, but their output drops as it gets colder, like any air-source heat pump. Most installs in Ontario have a backup: an electric element or a boiler. The heat loss decides how big the backup has to be.

Why do they pair so well with radiant floors?

Heat pumps are most efficient making lukewarm water, and radiant slabs need lukewarm water. Old cast-iron radiators that need very hot water are a much harder match.

Can an air-to-water heat pump also cool the house?

With fan coils, yes. Cooling through a radiant floor is limited, because a cold floor can sweat in humid weather. Plan cooling as part of the design if you want it.

Why is it hard to find an installer?

It is still a small part of the Ontario market, and it mixes heat pump work with hydronic work. A clear design helps a good installer price and build it right.

Do they qualify for rebates?

Check whether the specific model qualifies before you buy. Rebate programs list eligible equipment, and rules change. See the rebate guide.

Low Temperature, High Comfort
Radiant Designed for a Heat Pump

Send your drawings. We calculate the heat loss and design the radiant system to run at the lowest water temperature possible, with backup sized to the gap.

  • CSA F280 at your exact design temperature
  • Radiant layout for low water temperatures
  • Ventilation summary (RMVDS) for the permit
  • BCIN-stamped for the permit
  • From $395, 48-hour delivery
Get Your Free Quote
Tell us your municipality, home size and current furnace if known.
Secure · No spam · No obligation to buy
Ontario Heat Loss & BCIN Design Permit-ready heat loss calculations, HVAC design, and BCIN-stamped mechanical drawings for homeowners, builders, and designers across Ontario. Fast turnaround: free quote in 24 hours, most reports delivered within 48 hours after payment. Call 705-533-1633.
© 2026 Ontario Heat Loss & BCIN Design. All rights reserved.
BCIN CSA F280-12 Province-Wide
Building in Georgian Bay or Simcoe County? This site is run by the team at ICFhome.ca — 300+ custom homes since 1979. Our ICF showhome heats for about $100/month at the coldest. 705-533-1633