HRV Balancing and Winter Settings: How to Run Your HRV in an Ontario Winter Without Drafts or Sweating Windows

Most HRVs in Ontario houses are installed, plugged in and never touched again. Some were never balanced. Some get switched off in November because “it was blowing cold air.” Then the owner wonders why the windows are dripping.

Here is what balancing is, why your inspector may want it tagged, and how to set and care for an HRV through a real winter.

An HRV that was never balanced is a guess with a fan in it.
Ventilation Designed Right
Ventilation design and the ventilation summary (RMVDS) for your permit, with the design airflows your installer balances to.
Free quote · No spam · No obligation
What Balancing Is

An HRV brings fresh air in and sends stale air out. Balancing means measuring both airflows and adjusting them until they match the design. In and out, equal.

Unbalanced, the HRV either pushes the house positive, which can drive moisture into the walls, or pulls it negative, which brings in cold drafts and can pull air back down a chimney.

Many Ontario municipalities want the HRV installed, balanced and tagged before occupancy. Your installer measures and records the airflows. The design airflows come from your ventilation summary (RMVDS).

The design comes first

Your installer balances to numbers. Those numbers are on the ventilation design. No design, nothing to balance to.

Running It Through the Winter

Leave It On

Winter is when a tight house needs fresh air most. Continuous low speed is the normal setting.

Use High Speed When It Counts

Showers, cooking, a house full of people. Then back to low.

Lower the Humidity as It Gets Colder

Many HRV and window makers suggest lower indoor humidity on very cold days. Wet windows mean it is too high.

Watch the Outside Hoods

Snow and frost can block the intake and exhaust. Check them after a storm.

Clean the Filters

Check them every couple of months. Dirty filters choke the airflow.

Clean the Core

At least once a year, following the maker’s instructions.

Wet Windows? Check These First

1. Is the HRV On?

Turned off or on its lowest setting all winter is the most common cause.

2. Is the Humidity Too High?

Showers, cooking, laundry, plants and people all add moisture.

3. Was It Ever Balanced?

An unbalanced HRV may not be moving the air it should.

4. Is It the Right Size?

An undersized unit cannot keep up. That is a design question. See HRV selection.

It Starts With the Design

A good HRV install starts with a ventilation design: how much air the house needs, where the supplies and exhausts go, and how it ties into the heating. That design goes into the ventilation summary (RMVDS) for your permit and gives your installer the numbers to balance to. See HRV and ERV design and HRV vs ERV.

Building or renovating? We do the ventilation design and the RMVDS with your heat loss, so the installer has numbers to balance to.

Get Free Quote →
HRV Questions
What does it mean to balance an HRV?

Measuring the fresh air coming in and the stale air going out, and adjusting until they match the design airflows. An unbalanced HRV pushes or pulls on the house, which wastes energy and can cause drafts, condensation or backdrafting.

Does my HRV have to be balanced for the final inspection?

Many Ontario municipalities want the HRV installed, balanced and tagged before occupancy. Ask your building department what they want to see.

Should I turn the HRV off in winter?

No. Winter is when a tight house needs fresh air most. Run it continuously at its normal low speed and use high speed for showers, cooking or a full house.

What humidity should my house be at in winter?

Lower as it gets colder outside, or your windows will sweat. Many HRV and window makers suggest dropping indoor humidity on very cold days. Follow your unit’s guide and watch the windows: condensation means too much moisture or not enough ventilation.

How often should I clean the HRV?

Check the filters every couple of months and clean the core at least once a year, following the maker’s instructions. Check the outside hoods after snowstorms. A blocked intake hood is a common winter problem.

Why do my windows sweat even with an HRV?

Usually indoor humidity is too high for the outdoor temperature, the HRV is set too low or turned off, or it was never balanced. Sometimes the windows themselves are cold. Start with the settings and the balance.

Fresh Air, Designed
Ventilation Design and the RMVDS

Send your drawings. We do the heat loss, the ventilation design and the RMVDS together, with design airflows your installer can balance to.

  • Ventilation design with design airflows
  • Ventilation summary (RMVDS) for the permit
  • CSA F280 heat loss to match
  • BCIN-stamped for the permit
  • From $395, 48-hour delivery
Get Your Free Quote
Tell us your municipality, home size and current furnace if known.
Secure · No spam · No obligation to buy
Ontario Heat Loss & BCIN Design Permit-ready heat loss calculations, HVAC design, and BCIN-stamped mechanical drawings for homeowners, builders, and designers across Ontario. Fast turnaround: free quote in 24 hours, most reports delivered within 48 hours after payment. Call 705-533-1633.
© 2026 Ontario Heat Loss & BCIN Design. All rights reserved.
BCIN CSA F280-12 Province-Wide
Building in Georgian Bay or Simcoe County? This site is run by the team at ICFhome.ca — 300+ custom homes since 1979. Our ICF showhome heats for about $100/month at the coldest. 705-533-1633