SB-12 Energy Efficiency in Ontario: Packages, Paths and the Paperwork That Gets Your Permit Through

Every new Ontario house, and a lot of additions and conversions, has to prove it meets the energy rules before the permit is issued. In Ontario those rules live in Supplementary Standard SB-12, not in 9.36. If your designer keeps saying 9.36, that is your first warning sign.

Here is how SB-12 works in plain English: the two climate zones, the two ways to comply, the form the examiner wants, and the mistakes that send drawings back.

Energy form missing or wrong? That is one of the most common reasons a house permit gets bounced.
Get the Energy Side Done Right
Heat loss, HVAC design and the SB-12 energy form, all matched to the same drawings. BCIN-stamped, 48 hours.
Free quote · No spam · No obligation
What SB-12 Actually Is

SB-12 is a supplementary standard to the Ontario Building Code. It sets the minimum energy performance for houses: how much insulation, how good the windows, how efficient the furnace or heat pump, the HRV, and the water heater.

It does not tell you what size furnace to buy. That comes from the CSA F280 heat loss. SB-12 sets the minimum quality of the house. F280 measures how much heat that house needs on the coldest day. You need both on a permit, and they have to agree with each other.

Ontario is split into two SB-12 climate zones. Zone 1 is the warmer south, under 5,000 heating degree days. Zone 2 is 5,000 degree days and colder, which covers northern Ontario, roughly North Bay and Sudbury and up. Most of Southern Ontario, including Muskoka, is Zone 1. Your zone picks which table of packages you use.

The 9.36 trap

Section 9.36 is the national code’s energy section. Ontario does not use it for houses. Designers who work in several provinces sometimes copy 9.36 language onto Ontario drawings. Examiners notice. It costs you a resubmission and a couple of weeks.

The Two Ways to Comply

Prescriptive: pick a package

You choose a compliance package for your zone and your heating fuel, then build to its list: ceiling, wall, basement and slab insulation, window U-value, minimum furnace or heat pump efficiency, HRV efficiency, water heater efficiency, and in some packages a drain water heat recovery unit. No modelling. Cheapest and fastest.

Performance: model the house

An energy modeller builds a computer model of your actual house and proves it uses no more energy than the same house built to the package. Most Ontario modellers use NRCan’s HOT2000 software. Costs more, but lets you trade: more glass here, better walls there.

Other recognized programs

Some recognized energy programs can be used to show compliance. If you are building to one, ask your building department which programs they accept before you count on it.

For a typical house with normal windows, the prescriptive path is the right answer nine times out of ten. You go the performance path when the house does not fit a package: walls of glass facing the lake, an unusual heating system, or a design where you want to trade one thing for another.

Where SB-12 Paperwork Goes Wrong

1. Window Area Over the Limit

The packages assume a limited amount of glass compared to wall area. Big view windows push you over. Then you are on the performance path whether you planned it or not. Count the glass before you pick a package.

2. Package Does Not Match the Drawings

The form says R-60 in the ceiling and the section drawing says R-50. The form says a 95% furnace and the mechanical says something else. The examiner checks one against the other.

3. Wrong Zone

A lot sitting right on the Zone 1 and Zone 2 line needs the right zone. Guess wrong and every number on the form is wrong with it.

4. Missing the HRV or DWHR

Some packages require heat recovery equipment. If the package needs it and the drawings do not show it, it comes back.

5. Heat Loss Done on Old Values

The F280 has to use the same insulation and window values as the energy form. A heat loss done on a guess will not match.

6. Two Systems, One Form

A house with a gas furnace upstairs and a heat pump in a basement unit may need the energy side shown for each part. Ask before you submit.

ICF, Radiant and SB-12

We build ICF homes, so we see this from both sides. ICF walls usually meet or beat the wall insulation in the packages, and they are tight. That gives you room to work with on the performance path.

Radiant floors need their own care on the energy form. Slab insulation under heated floors is not optional, and the heat source still has to meet the package efficiency. Do it right and an ICF house with radiant floor heating is cheap to heat. Do it wrong and you are heating the ground under the slab.

Building new? We match the heat loss, the HVAC design and the energy form to the same set of drawings, so nothing disagrees.

Get Free Quote →
SB-12 Guides on This Site

Energy Efficiency Design Summary

The form the examiner wants and how to fill it in without getting it bounced. Read the EEDS guide.

2024 OBC HVAC Changes

What changed for heating and ventilation on January 1, 2025. Read the changes.

ICF Home Heat Loss

Why ICF houses need a real calculation, not framing defaults. Read the ICF guide.

HRV and ERV Design

Picking and sizing the heat recovery ventilator the package calls for. Read the HRV guide.

What Is an MVDS?

The ventilation summary that goes with your permit. Read about the MVDS.

Schedule 1

Who signs the design and what goes on the form. Read about Schedule 1.

SB-12 Questions We Get
Is SB-12 the same as OBC 9.36?

No. Section 9.36 is the energy section of the National Building Code. Ontario does not use it for houses. Ontario houses show energy compliance through Supplementary Standard SB-12, which the Ontario Building Code points to. If someone quotes you 9.36 for an Ontario house, they copied from the wrong code book.

Do I need SB-12 for an addition or a renovation?

Usually yes for the new or changed parts. An addition, a basement you are finishing as living space, or a conversion of a seasonal building to a full-time home all have to meet the energy rules for the work you are doing. The examiner will want an energy form with the permit. Ask your building department exactly which form they want for your project.

What is the difference between the prescriptive and performance path?

Prescriptive means you pick a package and build to its list: insulation, windows, furnace efficiency, HRV and so on. No modelling. Performance means an energy modeller proves your actual design uses no more energy than the package house would. Prescriptive is cheaper and faster. Performance gives you freedom, and you pay for the modelling.

Who fills out the energy form?

The designer responsible for the energy design fills it in and signs it. For most houses that is the BCIN designer doing the drawings or the mechanical. An owner building their own house can do it under the owner exemption, but the form still has to be right.

Does ICF help with SB-12?

Yes. ICF walls usually meet or beat the wall requirement in the packages, and they are very airtight. On the performance path that extra wall performance can pay for things you want elsewhere, like more glass.

Does SB-12 change my furnace or heat pump size?

SB-12 sets minimum efficiencies, not the size. The size comes from the CSA F280 heat loss. But a better envelope from SB-12 lowers the heat loss, so the equipment usually gets smaller. That is money back.

One Set of Numbers
Heat Loss, HVAC and Energy, All Matching

Send us your drawings. We do the CSA F280, the HVAC design and help with the energy form so the examiner sees one story, not three.

  • CSA F280 at your exact design temperature
  • Duct or radiant layout to match
  • Values matched to your SB-12 package
  • Ventilation summary (RMVDS) for the permit
  • BCIN-stamped, Schedule 1 included
  • From $395, 48-hour delivery
Get Your Free Quote
Tell us your municipality, home size and current furnace if known.
Secure · No spam · No obligation to buy
Ontario Heat Loss & BCIN Design Permit-ready heat loss calculations, HVAC design, and BCIN-stamped mechanical drawings for homeowners, builders, and designers across Ontario. Fast turnaround: free quote in 24 hours, most reports delivered within 48 hours after payment. Call 705-533-1633.
© 2026 Ontario Heat Loss & BCIN Design. All rights reserved.
BCIN CSA F280-12 Province-Wide
Building in Georgian Bay or Simcoe County? This site is run by the team at ICFhome.ca — 300+ custom homes since 1979. Our ICF showhome heats for about $100/month at the coldest. 705-533-1633